The TM3000 is Hitachi High Technologies latest Tabletop Microscope. New features include variable accelerating voltage, higher beam current, larger stage and chamber, and smaller footprint.
The XE-100 is our flagship AFM with reduced drift rate and the Step-and-Scan Automation that provides the ultimate AFM/SPM performance in Non-Contact nanoscale metrology.
The IR-OBIRCH Analysis System "μAMOS" is a semiconductor failure analyzer which uses IR-OBIRCH (Infrared Optical Beam Induced Resistance CHange) method for localization of leakage current path and the abnormal resistance part of contacts (via contact) in LSI devices.
The PHI 5000 VersaProbe is a multi-technique surface analysis instrument based on PHI's highly successful scanning x-ray microprobe technology.
The FB2200 allows for rapid and precise specimen preparation for both transmission and scanning electron microscopy of semiconductors and other advanced materials.
SIGMATECH, INC.
B136 L1 C. Arellano St.
Katarungan Vill., (Daang Hari), Poblacion
Muntinlupa City 1776, Philippines
Phone - (632)358-5889 (Service)
- (632)576-8913 (Sales)
- (632)576-1599 (Admin/Accounting)
Fax - (632) 807-8392
Hotlines - 0928 503-3281 (Smart)
- 0917 847-5730 (Globe)
Email - sales@sigmatech-inc.com
- service@sigmatech-inc.com
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| CUSTOMIZED GC | ![]() |
Customized GC - Tailored Solutions |
| NGA GPA 2261-AC | ![]() |
NGA GPA 2261 - Natural Gas Components Test Methods ASTM D1945, ISO 6974 AC Analytical Controls by PAC offers a solution to characterize the composition of natural gases according to GPA 2261 with results within 25 minutes. |
| NGA GPA 2286-AC | ![]() |
NGA GPA 2286 - Natural Gas Components Test Methods ASTM D1945, ISO 6974 AC Analytical Controls offers a solution to characterize the composition of natural gases according to GPA 2286 with results within 70 minutes.. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| CUSTOMIZED GC | ![]() |
Customized GC - Tailored Solutions |
| HiSpeed RGA-AC | ![]() |
HiSpeed RGA - Refinery Gas Components Test Methods ASTM D2163, ASTM D2504, ASTM D2505, ASTM D2598, ASTM D3588, EN ISO 7941, IP 405, ISO 7941 AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| Reformulyzer-AC | ![]() |
Hydrocarbon Group Type Analysis Test Methods - ASTM D5443, ASTM D6839, EN 14517, IP 382, IP 566, ISO 22854, EN ISO 22854 AC Analytical Controls Reformulyzer Mark 3 (M3) provides complete identification and quantification of all hydrocarbon types, oxygenates, and carbon number distribution with numerous features. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| SIMDIS-AC | ![]() |
Test Methods
ASTM D2887, ASTM D3710, ASTM D5307, ASTM D6352, ASTM D7096, ASTM D7169, ASTM D7213, ASTM D7398, ASTM D7500, EN 15199, EN ISO 3924, IP 406, IP 480, IP 507, ISO 3924 AC Analytical Controls, the global SIMDIS market leader, provides a full range of solutions that accurately determine true boiling point data from naphtha up to crude oil samples. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| FAME in AVTUR Analyzer | ![]() |
FAME in AVTUR Analyzer - FAME Traces in Aviation Turbine Fuel High End Solution for the Analysis of FAME Traces in Aviation Turbine Fuel using Gas Chromatography.AC developed a GC application with a unique combination of Deans-Switchingand Re-Focusing. It is specifically designed so that it can be used for routine analysis by refineries, distribution/pipeline companies, independent labs, airline companies, military, or any other party for the measurement of FAME (biodiesel) in jet fuel. |
| NGA GPA 2261 | ![]() |
NGA GPA 2261 - Natural Gas Components - Test Methods ASTM D1945, ISO 6974 AC Analytical Controls by PAC offers a solution to characterize the composition of natural gases according to GPA 2261 with results within 25 minutes. The AC NGA GPA 2261 Analyzer determines:C1 C6, C6+ hydrocarbons, Inert gases: nitrogen, carbon dioxide and oxygen, Hydrogen sulfide |
| All-in-One Biodiesel | ![]() |
All-in-One Biodiesel Test Methods ASTM D6584, EN 14103, EN 14105, EN 14106, EN 14110, EN 15721 AC Analytical Controls All-In-One Biodiesel analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results within minutes. All-In-One Biodiesel is a chromatographic solution that complies with all ASTM EN test methods listed in the biodiesel specifications EN 14214 ASTM D 6751. |
| D5501 | ![]() |
D5501 - Ethanol Content of Denatured Fuel Ethanol Test Methods - ASTM D5501 Applications: BioFuels, Oxygenates |
| HiSpeed RGA | ![]() |
HiSpeed RGA - Refinery Gas Components Test Methods: ASTM D2163, ASTM D2504, ASTM D2505, ASTM D2598, ASTM D3588, EN ISO 7941, IP 405, ISO 7941 AC Analytical Controls offers the Hi-Speed Refinery Gas Analyzer, a high speed solution that determines and reports the composition of refinery gas streams in only five minutes. |
| Reformulyzer | ![]() |
Hydrocarbon Group Type Analysis Test Methods>: ASTM D5443, ASTM D6839, EN 14517, IP 382, IP 566, ISO 22854, EN ISO 22854 AC Analytical Controls Reformulyzer Mark 3 (M3) provides complete identification and quantification of all hydrocarbon types, oxygenates, and carbon number distribution with numerous features. Full gasoline analysis in 75 minutes (in compliance with ASTM D 6839, EN 14517, IP 526 and ISO/AWI work item 22854) ensures that results are precise and accurate. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| CUSTOMIZED GC | ![]() |
Customized GC - Tailored Solutions The AC solution portfolio matches almost the entire spectrum of petroleum, petrochemical and natural gas analysis needs. Beginning with the light end analysis of gas, naphtha and gasoline streams, AC standard solutions progress up to and include the analysis of heavy streams such as crude oil and residual. |
| Sulfur Traces-AC | ![]() |
7090 detector w/ GC Test Methods - ASTM D5504, ASTM D5623, GPA 2199-99 Applicated GC Gas Analysis, Sulfur Trace Analysis, Petrochemical Analysis |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| FTO D6296-AC | ![]() |
Fast Total Olefin Analysis Test Methods - ASTM D6296 Determine aromatic content of diesel and aviation turbine fuels olefin content of gasoline with AC Analytical Controls Supercritical Fluid Chromatograph (SFC). |
| SFC-AC | ![]() |
Test Methods
ASTM D5186, ASTM D6550 Determine aromatic content of diesel and aviation turbine fuels olefin content of gasoline with AC Analytical Controls Supercritical Fluid Chromatograph (SFC). |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| DHA-AC | ![]() |
Test Methods -
ASTM D5134, ASTM D6729, ASTM D6730, ASTM D6733 AC Analytical Controls offers a full range of detailed hydrocarbon analyzers for flexible and reliable component identification. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| D5501-AC | ![]() |
D5501 - Ethanol Content of Denatured Test Methods - ASTM D5501 The AC Aromatics (ASTM D 5580) application measures the aromatic content in gasoline by determining:Benzene,Toluene,Ethylbenzene,Xylenes,C9 and heavier aromatics Total aromatics |
| D5580/D4815-AC | ![]() |
D5580/D4815 - Aromatics and Oxygenates Test Methods ASTM D4815, ASTM D5580, EN 15721 Determines traces of oxygenates in light petroleum streams.AC Analytical Controls developed the AC OxytracerTM to check naphtha for the presence of oxygenate impurities in 20 minutes. |
| Oxytracer-AC | ![]() |
Oxytracer - Traces Oxygenates Test Methods - EN 13132 |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| CUSTOMIZED GC | ![]() |
Customized GC - Tailored Solutions |
| D3606-AC | ![]() |
D3606 - Benzene Test Methods - ASTM D3606, EN 12177 The AC Benzene/Toluene (ASTM D 3606) analyzer separates benzene from both light and heavy hydrocarbons, the internal standard, and toluene, in a single analysis. |
| D5580/D4815-AC | ![]() |
D5580/D4815 - Aromatics and Oxygenates Test Methods ASTM D4815, ASTM D5580, EN 15721 The AC Aromatics (ASTM D 5580) application measures the aromatic content in gasoline by determining: Benzene,Toluene, Ethylbenzene,Xylenes,C9 and heavier aromatics Total aromatics |
| MDA IP391-AC | ![]() |
MDA IP391, EN12916, D6591 - Aromaticity Test Methods - ASTM D6591, EN 12916, IP 391 To assist refiners in determining the aromatic content of diesel fuels, AC Analytical Controls developed a fast, robust and easy-to-use systemThe AC Mid Distillates Analyzer (MDA). |
| SFC-AC | ![]() |
Test Methods -
ASTM D5186, ASTM D6550 Determine aromatic content of diesel and aviation turbine fuels olefin content of gasoline with AC Analytical Controls Supercritical Fluid Chromatograph (SFC). This chromatographic system exceeds ASTM specifications and is superior to gas chromatography and liquid chromatography. |
| product name |
image (click to enlarge) |
description |
|---|---|---|
| Page Top | ||
| All-in-One Biodiesel-AC | ![]() |
All-in-One Biodiesel Test Methods - ASTM D6584, EN 14103, EN 14105, EN 14106, EN 14110, EN 15721 AC Analytical Controls All-In-One Biodiesel analyzer quickly determines the quality of fatty acid methyl esters (FAME) blending stock for diesel fuel, and yields results within minutes. All-In-One Biodiesel is a chromatographic solution that complies with all ASTM EN test methods listed in the biodiesel specifications EN 14214 ASTM D 6751. |
| D5501-AC | ![]() |
D5501 - Ethanol Content of Denatured Fuel Ethanol Test Methods - ASTM D5501 BioFuels, Oxygenates |